2006 Infiniti G35, Power Seat Not Working

This 2006 Infiniti G35 came in with the complaint that the driver’s power seat would not move back to front. The customer had already had it checked and was told that the seat base would have to be replaced, $700 for the part plus labor. He asked me if I would take a look at … Continue reading “2006 Infiniti G35, Power Seat Not Working”

2002 Oldsmobile Intrigue, No A/C Vent Control

This 2000 Oldsmobile Intrigue came in the complaint that the a/c vent positions could not be controlled. It would just blow out of every location a little, but no where with any force. This Olds Intrigue has auto a/c controls. It has an electric over vacuum control  system for operating the door positions. The first … Continue reading “2002 Oldsmobile Intrigue, No A/C Vent Control”

2003 Chevrolet Impala, Gauges and A/C Compressor Turn Off After 5-10 Miles of Driving

This 2003 Chevrolet Impala came in with the complaint that the dash gauges and a/c compressor turn off after 5-10 miles of driving. There were dozens of codes stored in multiple modules and I seem to remember a reference to low  voltage. I eventually wound up in “Engine Data 2” to find the data line … Continue reading “2003 Chevrolet Impala, Gauges and A/C Compressor Turn Off After 5-10 Miles of Driving”

2003 Chevrolet Suburban, No Blower Speeds 2 and 4

This  2003 Chevrolet Suburban came in with the complaint that the blower had lost speeds number 2 and 4. The customer was very concerned that the other speeds would soon fail too. This Chevy Suburban has manual HVAC controls so it uses a blower resistor assembly. Make sure the ignition remains off and remove the … Continue reading “2003 Chevrolet Suburban, No Blower Speeds 2 and 4”

2004 Chevrolet Tahoe Multiple Problems, No Communication

This 2004 Chevrolet Tahoe came in with a multitude of complaints. Some of the complaints were that it might not start, the power windows would stop working, the door locks would cycle, the radio would stop working, the instrument cluster gauges would stop working and  multiple warning lights would come on. From a technical perspective … Continue reading “2004 Chevrolet Tahoe Multiple Problems, No Communication”

2002 Buick Century No Low Blower Speeds

This 2002 Buick Century came in with the complaint that the lower blower speeds do not work. This Century has manual air conditioning controls. I have been down this road many times and it is just a faulty blower resistor. I will give actual testing information later, but for now I am just going to … Continue reading “2002 Buick Century No Low Blower Speeds”

2000 Ford Taurus, A/C Not Working, Fuse #28 / #128 Blows

This 2000 Ford Taurus came in with the complaint that the a/c did not work. The customer had already figured out that the 15 amp fuse number 28 in the underhood fuse box was blown. It is worth noting that in the wiring diagrams that fuse is referred to as fuse number 128. Power on … Continue reading “2000 Ford Taurus, A/C Not Working, Fuse #28 / #128 Blows”

2002 GMC Sierra Blower Works Sometimes

This  2002 GMC Sierra came in with the complaint that the blower would work sometimes, but now, it would not work at all.  This truck has manual HVAC controls so it uses a blower resistor assembly. I do not recommend disconnecting the battery while this work is being done. Instead make sure the ignition remains … Continue reading “2002 GMC Sierra Blower Works Sometimes”

1988 Cadillac Brougham, Windshield Wipers Do Not Work

This 1988 Cadillac Brougham came in with the complaint that the windshield wipers do not work. I have not worked on one of these in quite a while but I do remember the common problem with the rear wheel drive Cadillac wiper switches. I checked the feel of the switch and sure enough,  it “felt” … Continue reading “1988 Cadillac Brougham, Windshield Wipers Do Not Work”

2003 GMC Yukon Bower Erratic / Not Working

This 2003 GMC Yukon came in with the complaint that the blower was doing weird things. The blower sometimes would not turn off when the ignition was turned off. Also sometimes the blower worked and sometimes it did not. Withe the local temperature expected to top off at over 100 degrees F  and the the … Continue reading “2003 GMC Yukon Bower Erratic / Not Working”