2003 Chrysler Town and Country Van came in with the complaint of the blower operates on high speed with key on and cannot be adjusted down. This procedure will also apply to Dodge Caravans with auto a/c. The controls and indicators seemed to work normally. I checked the wiring diagram and component locator and found that the blower power module is located behind the glove box. Good place to start.
After opening the glove box there are two stops the have to be depressed inward in order to drop the box down.
The blower power module is directly behind the lowered glove box. It is held in place by two 8mm hex head screws.
After removing the two attaching screws, the blower power module can be positioned for testing.
Turn the key on and while manually rotating the blower switch from low to high you should see a voltage change between about 2 volts (high)up to about 10 volts (low) on the blue/light blue wire. It is the middle wire in the left connector pictured below. Because the blower was working on high speed there was no need to do any other testing, however if you were to have low blower or no blower you would need to test further. Check for 12 volts – on the black/orange wire and 12 volts+ on the dark blue wire in the three wire connector. If either is missing check respective fuse and ground connections. Next check for 12 volts between the blue wire and the dark blue /yellow (sometimes black as pictured below) wire in the two wire connector to the right of the pictures. If either signal is missing in the two wire connector and the three wire connector tested good then the power module is faulty. If 12 volts power and ground are present then the blower motor is faulty. Usually bumping the motor with the key on and the blower switch on high will make the motor work for a little while because it will reset the worn brushes.
Three wire connector:
Black/Orange wire should have a constant ground.
Dark Blue wire should have 12 volt switched power from the front blower relay. The front blower relay is located in the Integrated Power Module (underhood fuse box).
Blue/Light Blue wire should have a varying voltage from about 2 volts(high blower command) and a nominal 10 volts(low blower command).
Two wire connector:
Check for a nominal battery voltage reading across the two wires. Key on and blower set to high.
I removed the mounting screws to gain better access to the wiring for testing.
Be careful to keep the aluminum cooling fins away from the metal brace for the glove box. It will complete the ground circuit for the blower motor and will scare you when it sparks.
Place an insulating cloth between the aluminum fins and the brace if you want.
A good look at the blower power module.
Installed the new blower power module and all is well.
Sparky I am real slow, but the problem was the ground connection from the blower motor to the blower power module. Cut the connector off and used two spade connectors and everything is working. Thank you.
I am assuming that you meant cooling fins were very hot? If so that would indicate that the module is trying to power up a faulty blower motor. If you had it connected like that for very long the new controller may already be damaged.
I am getting no blower at all. I changed the resistor and it did not come on. When I uninstalled it the cooling fans were burning hot.
Sparky received another control module and the front fan still does not work. I swapped out the 40a fuses and blower relays and no change. I noticed one condition – with the rear control system set to auto, the fan selector speed knob does not change the fan speed. Is that natural? Thanks
Have you done any testing and if so what were your results?