This is a very common problem on 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006 and 2007 Chevrolet Silverado and GMC Sierra trucks. Over a period of time the resistor and usually the connector overheat and blower operation stops in some or all speeds.
The blower resistor is located on the passenger side of the vehicle behind the glove box. There is a plastic cover that has to be removed to gain access to the resistor and wiring.
After the cover is removed disconnect the harness connector and inspect for damage. On this particular vehicle the only terminals that were damaged were the third from the right and the third from the left. Sometimes all of the terminals will be damaged and the plug will be melted to the resistor as shown in the last pictures.
After thoroughly inspecting the connector for damage the terminal retaining comb was removed from the old and the new harness connectors. The good wiring was transferred one at a time from the old connector to the new connector. A terminal extracting tool is needed to do this. The locking tab must be slightly depressed before the terminal can be removed from the connector. A solid piece of wire such as a larger paperclip could be used if a tool is not available. If you do not have an adequate tool or experience this should not be done. Cut the wires one at a time and splice in to the harness using a quality butt connector.
Be sure to stagger the spliced connectors as much as possible in order to have a neater and less troublesome repair.
Retape the harness and install the new blower resistor and harness connector. As with any wiring repair that involves a burnt connector, the connector and the component that it attaches to must be replaced at the same time or the repair will fail very quickly.
This connector like many that will be found was melted to the resistor and every wire had to be replaced. You can save yourself time and money by always being aware of changes in your vehicle and repairing them as soon as possible. If you need quality parts click here.
I recently completed a video on this repair as well. Please click here to view.
I am adding testing instructions due to popular demand. Testing is as follows. Disconnect the 7 wire harness connector and inspect. If there is any sign of heat damage replace both parts per above instructions. If there is no sign of heat damage then check the following. With the 7 wire harness disconnected check for power on the red wire. It should have 12 volts at all times and it gets it’s power from the 40 amp blower fuse in the under hood fuse box. Next with the key on check for 12 volt power to each of the following wires as you move the blower speed switch from low to high. Yellow / low, tan / med 1, lt blue / med 2, purple / med 3 and orange / high. Remember, this test is done with the key on and the seven wire harness disconnected. Other than the red wire having power at all times, only one wire at a time will have power on it, during a proper test. If there is no power to any of these wires during the test , check the fuse in the driver’s interior fuse box. If only some of these signals are missing, you will need to inspect the blower speed switch and related wiring. Also you should do a drag test on the terminals to check the spring tension. Please click here for more instructions
- Terminal “A” Tan = Speed 2, power through blower switch from HVAC fuse
- Terminal “B” Yellow = Speed 1, power through blower switch from HVAC fuse
- Terminal “C” Purple = Speed 4, power through blower switch from HVAC fuse
- Terminal “D” Lt Blue = Speed 3, power through blower switch from HVAC fuse
- Terminal “E” Black = Blower system, ground at all times
- Terminal “F” Orange = Speed 5, power through blower switch from HVAC fuse
- Terminal “G” Red = Speed 5, Constant power from BLWR fuse under hood
If for some reason the blower does not work at all and there is no power on any of the wires except the red , you may want to see the recent information I published about a new problem that has occurred. Please click here to see that article.
If all of the tests above are okay and you want to go a step further, place a test light or voltmeter in the wires going to the blower motor. If the light comes on or you have a 12 volt reading, the resistor and wiring are okay and the blower motor is faulty. This can also sometimes be confirmed by bumping the blower motor with the switches on. If the motor starts after bumping the motor is faulty. One can also remove the blower motor and apply 12 volts (power and ground) directly to the motor. Be careful though the motor will tend to jump and roll all over the place. Hold it firmly and be sure you are clear of the impeller as it could hurt you pretty easily.
One other note. If you have an amperage gauge, test the blower amperage draw while it is mounted in the blower case. Turn on surge amperage could go up to about 28 amps. Amperage draw at high blower should be in the 18 to 24 amp range. The lower the better. Restricted cabin air filters (if present) and dirty evaporator cores will cause a blower motor to draw more current while reducing air flow volume. These two conditions combined will significantly reduce the life of any blower resistor.
More additions to make parts identification hopefully easier. The following picture is of a floor mounted center console. In ordering, this is one of the most important features that we need to know about your truck. Please be sure to leave this information along with year, make, model, engine size, type of cab (regular, extended or four door) and confirmation that you have manual a/c. Leave this info in the customer comments box at check out when ordering. You may also email us anytime or call us 8:00 am to 6:00pm EST
The following picture is of an original two piece blower resistor that has been updated to a new design which is a single piece unit. If your truck has the two piece resistor, both pieces must be removed before replacing with the new single piece resistor.
If you have any questions related to this post please email me at info@the-electric-connection.com I just finished a video on this as well. Please click here to view.
Ok so it’s Texas deep south today. When I went to work it was already hot. Said, I had enough, was going to take it to the shop in the AM. Already replaced blower, resistor and pigtail. So I just went outside and tried to ground it. Just got sparks. Granted it’s 4am right now, said the hell with it and dropped down the glove box with the truck running and A/C on, no blower of course. Reached back to the wiring harness. There is what feels like an individual wire runs towards the firewall, I think. Wiggled it and yaba daba doo the blower kicked in no more sweaty nads in slacks and dress shirt headed to work 🙂 Hope this helps some of you. I have a 2002 GMC Sierra single cab step side v6. Good luck
Since your truck is a 1996 model you should find the information at the following post address more useful. You will need to copy and post the address. Also there are two other posts that go along with it. Total of three parts to this repair.
http://www.sparkys-answers.com/2010/11/1997-gmc-c1500-pickup-no-blower.html
I have a 96 silverado. For months i only had speed 5. then, when that finally stopped working as well, i decided to fix the problem. A little searching led me to the blower resistor. Replaced it today (talk abouit a space for smallhands!) and now i get all speeds except speed 5. I looked at the connector for damage but didn’t see any. I’m having trouble understanding in your explanation exactly how speed 5 works. Is there a separate wire for Speed 5 only, or is my problem in the connector and i’m just not seeing it? Thanks a lot!
Your blower motor will need to be replaced. Please read the information at the following post address. You will need to copy and paste it. Pay particular attention to the end of the article in red font.
http://www.sparkys-answers.com/2011/07/2003-gmc-yukon-bower-erratic-not.html
I had pretty much the same issues on my 2003 Trailblazer (with Auto), Blower running with key off. Replaced the resistor with harness(Echlin). Now I have have to pull the fuse while the truck is running to get the blower working. Otherwise everything works fine while the trucks running. Kinda like a computer reboot?