2005 Chevrolet Silverado Blower Inop

This is a very common problem on 1999, 2000, 2001, 2002, 2003, 2004, 2005, 2006 and 2007 Chevrolet Silverado and GMC Sierra trucks. Over a period of time the resistor and usually the connector overheat and blower operation stops in some or all speeds.

The blower resistor is located on the passenger side of the vehicle behind the glove box. There is a plastic cover that has to be removed to gain access to the resistor and wiring.

After the cover is removed disconnect the harness connector and inspect for damage. On this particular vehicle the only terminals that were damaged were the third from the right and the third from the left. Sometimes all of the terminals will be damaged and the plug will be melted to the resistor as shown in the last pictures.

After thoroughly inspecting the connector for damage the terminal retaining comb was removed from the old and the new harness connectors. The good wiring was transferred one at a time from the old connector to the new connector. A terminal extracting tool is needed to do this. The locking tab must be slightly depressed before the terminal can be removed from the connector. A solid piece of wire such as a larger paperclip could be used if a tool is not available. If you do not have an adequate tool or experience this should not be done. Cut the wires one at a time and splice in to the harness using a quality butt connector.

Be sure to stagger the spliced connectors as much as possible in order to have a neater and less troublesome repair.

Retape the harness and install the new blower resistor and harness connector. As with any wiring repair that involves a burnt connector, the connector and the component that it attaches to must be replaced at the same time or the repair will fail very quickly.

This connector like many that will be found was melted to the resistor and every wire had to be replaced. You can save yourself time and money by always being aware of changes in your vehicle and repairing them as soon as possible. If you need quality parts click here.

I recently completed a video on this repair as well. Please click here to view.

I am adding testing instructions due to popular demand. Testing is as follows. Disconnect the 7 wire harness connector and inspect. If there is any sign of heat damage replace both parts per above instructions. If there is no sign of heat damage then check the following. With the 7 wire harness disconnected check for power on the red wire. It should have 12 volts at all times and it gets it’s power from the 40 amp blower fuse in the under hood fuse box. Next with the key on check for 12 volt power to each of the following wires as you move the blower speed switch from low to high. Yellow / low, tan / med 1, lt blue / med 2, purple / med 3 and orange / high. Remember, this test is done with the key on and the seven wire harness disconnected. Other than the red wire having power at all times, only one wire at a time will have power on it, during a proper test. If there is no power to any of these wires during the test , check the fuse in the driver’s interior fuse box. If only some of these signals are missing, you will need to inspect the blower speed switch and related wiring. Also you should do a drag test on the terminals to check the spring tension. Please click here for more instructions

  • Terminal “A” Tan = Speed 2, power through blower switch from HVAC fuse
  • Terminal “B” Yellow = Speed 1, power through blower switch from HVAC fuse
  • Terminal “C” Purple = Speed 4, power through blower switch from HVAC fuse
  • Terminal “D” Lt Blue = Speed 3, power through blower switch from HVAC fuse
  • Terminal “E” Black = Blower system, ground at all times
  • Terminal “F” Orange = Speed 5, power through blower switch from HVAC fuse
  • Terminal “G” Red = Speed 5, Constant power from BLWR fuse under hood

If for some reason the blower does not work at all and there is no power on any of the wires except the red , you may want to see the recent information I published about a new problem that has occurred. Please click here to see that article.

If all of the tests above are okay and you want to go a step further, place a test light or voltmeter in the wires going to the blower motor. If the light comes on or you have a 12 volt reading, the resistor and wiring are okay and the blower motor is faulty. This can also sometimes be confirmed by bumping the blower motor with the switches on. If the motor starts after bumping the motor is faulty. One can also remove the blower motor and apply 12 volts (power and ground) directly to the motor. Be careful though the motor will tend to jump and roll all over the place. Hold it firmly and be sure you are clear of the impeller as it could hurt you pretty easily.

One other note. If you have an amperage gauge, test the blower amperage draw while it is mounted in the blower case. Turn on surge amperage could go up to about 28 amps. Amperage draw at high blower should be in the 18 to 24 amp range. The lower the better. Restricted cabin air filters (if present) and dirty evaporator cores will cause a blower motor to draw more current while reducing air flow volume. These two conditions combined will significantly reduce the life of any blower resistor.

More additions to make parts identification hopefully easier. The following picture is of a floor mounted center console. In ordering, this is one of the most important features that we need to know about your truck. Please be sure to leave this information along with year, make, model, engine size, type of cab (regular, extended or four door) and confirmation that you have manual a/c. Leave this info in the customer comments box at check out when ordering. You may also email us anytime or call us 8:00 am to 6:00pm EST

The following picture is of an original two piece blower resistor that has been updated to a new design which is a single piece unit. If your truck has the two piece resistor, both pieces must be removed before replacing with the new single piece resistor.

If you have any questions related to this post please email me at info@the-electric-connection.com I just finished a video on this as well. Please click here to view.

128 discussions on “2005 Chevrolet Silverado Blower Inop”

  1. hello sparky my name is ryan from wv i left work turned on heater and it worked on low but the fan wouldnt turn up when i tried to so i cut vehicle off and turned back on and it worked on high but wouldnt turn down so i then cut vehicle off again and the heater kept running. i have pulled fuses and tried reseting it but it still works like it stated whatever speed its on when vehicle is turned off in is what speed it stays on. could u please tell me what might be wrong and where to begin adn what parts im looking at. thanks my vehicle is a 2007 chevy trailblazer with dual controls and either auto or manual heat controls.

  2. I have a 2005 Chevy Silverado, and lost speed 5 ~6 months ago. I lost speed 4 today for an hour or two, and then it worked again. I went to my local chevy dealer on the way home from work, and he told me about the resistor problem. He also told me to check the wiring harness to see if it was burnt. There was one burnt terminal. Just to make sure he was right, I replaced the resistor and cleaned the burnt terminal and turned things on to see if it would work before I spent the money on a new harness. Speed 5 didn’t work. I took the new resistor out, and reinstalled the old one so I can use the A/C until I can get to the part store to buy a new harness. After I plugged the old one back in, all of the speeds worked (even speed 5). Any idea why it suddenly started working?

    Do I really need a new resistor, or do I just need a new harness?

    Thanks,

    David

  3. The original circuit board type resistors had a high failure rate.GM updated the resistor to the current heavier design. This created a new problem in that the wires were not heavy enough to handle the load and became the new weak point. It is strongly recommended that the harness be updated to the heavier design when the resistor is changed. Regardless of how “good” it looks. Preventative maintenance.

  4. Why are you splicing wires during your resistor pack change out? If the wires are not burned the resistance should be the same. Is there a problem with the OEM design that causes the stock blower resistor to fail? Seems to me the resistor pack should not fail.
    I ask because I had a failure on my ’04 Suburban blower and pulled the pack. Everything was dry as a bone, but the resistor pack was blown apart in two places. Funny thing to happen after 100K miles. Anyway, a check of the wires revealed nothing. No hint of burned wires.

    What am I missing?