Air is blowing only through vents and won’t switch to defrost we already calibrated and changed the blend door actuator. What else could be the problem?

ID Status Date Year Make Model Transmission Type A/C Controls Public/Private
#13963 Closed 2004 Gmc Yukon public

Motor size 5.3. We have changed the blend door actuator already and still doesn’t change to defrost

Sparky

It may have just been a typing mistake but the actuator that will need to be replaced is the mode actuator above the gas pedal area. Could you provide the part number and location of the actuator that you have already replaced?

Write a reply

The ticket has been closed. If you feel that your issue has not been solved yet or something new came up in relation to this ticket, you can re-open it by clicking this link.