2003 GMC Yukon Bower Erratic / Not Working

This 2003 GMC Yukon came in with the complaint that the blower was doing weird things. The blower sometimes would not turn off when the ignition was turned off. Also sometimes the blower worked and sometimes it did not. Withe the local temperature expected to top off at over 100 degrees F  and the the index expected to reach 120 degrees F, the customer said it had to be fixed. I agree.

The first step is to remove two of the three 7 mm screws (center and right hand),  that hold the hush panel on under the passenger side of the dash.

With the hush panel dropped down, it is a quick test of the wiring, click here to see that information. The two most common failure symptoms with this part are an inoperative blower motor or a blower motor that will not turn off even with the key off. For testing information please see these repair articles. 2003 Chevrolet Silverado Blower  , 2004 Chevrolet Silverado Blower Will Not Turn Off. and 2005 Chevrolet Tahoe Blower Not Working  (video).

Using a screw driver or similar device, depress the locking tab and disconnect the wiring to the blower motor.

Remove the two screws holding the blower speed controller in place.

Push in the locking tab and disconnect the three wire connector from the blower speed controller.

Install the foam spacer on the hole marked 800 on the end of the unit that has four holes.

Mount the blower speed controller using the supplied screws. You will be using the mounting holes marked 800 on the new unit. Note the foam spacer under the left mount in the picture below.

Install the new wiring into the blower speed controller.

Connect the harness to the blower motor.

Cut and splice one wire at a time. Stagger the joints so that the wiring harness will be neat and trouble free.

Remove the BLWR fuse in the under hood fuse box before cutting the red wire. You might be tempted to disconnect the battery instead, but I do not recommend it. The act of disconnecting the battery does two things that can be detrimental: 1) Loses learned memory, which could result in a poor idle condition, and 2) Starts the recalibration procedure for the HVAC actuators, which may result in stuck HVAC doors and more expense.

Wrap tape back around the harness and put the hush panel back into place. Keep in mind that the old part number 15-80567 is no longer available and it has been replaced by this new kit.  If you need this blower speed controller kit, please click here.

Another one done.

I decided to do some updated testing due to the design change by GM. There is still a constant 12 volt signal on the Red wire and  constant ground on the Black wire.

Things have changed on the purple wire though with the new blower speed controller installation. One can test from the red wire to the purple wire or from the black wire to the purple wire with your voltmeter. GM recommend’s checking from the red to the purple but I prefer checking from the black to the purple. My reasoning is that it educates us that the blower speed controller has a nominal 12 volt output on the purple wire that the a/c control head signal brings down by applying a pulsed ground signal to. The chart starts at the highest blower position and descends one notch at a time to the lowest blower setting.

Red wire           Purple wire           Black wire          Scan Tool Duty Cycle
8.57 volts        Highest Speed         4.65 volts                     78%
6.65 volts        High -1                      6.75 volts                     59%
5.10 volts        High -2                      8.50 volts                     43%
4.08 volts        High -3                     9.65 volts                     33%
3.27 volts        High -4                    10.52 volts                     25%
2.71 volts        High -5                     11.15 volts                     20%
1.98 volts        High -6                    11.95 volts                     13%
1.32 volts        Lowest Speed         12.64 volts                      6%

Keep in mind that the voltage is due to the duty cycle of a switched ground from the a/c control head. In bench testing I have confirmed that applying a constant ground to the purple wire will only yield a single pulse from the blower motor. Repeating the applied ground multiple times in a short period will allow the motor to run. I do not know if this added info will help anyone or not but I thought it was at least interesting from a technical perspective.

There is a new development in this repair. It seems that General Motors has added or changed a circuit in the new module that reduces what they refer to as “Thermal Events”. In doing so the new module does not always play well with aged blower motors. What we wind up with is this. The blower motor will not work on an engine restart unless the a/c controls were switched off before the ignition was cycled off and back on after the engine is running again. The two immediate ways to address this issue is to learn to remember to cycle the switches in the above manner or replace the aged blower motor with a new one.  I  suspect there may be a software update somewhere down the road but that will require dealer level programming abilities. Since the replacement part is only available from GM or through an ACDelco distributor we are all being subjected to this problem.

There was not a software update but another part is now being supplied and so far with no unexpected issues. Click here for the new product link.

The latest design ACDelco part is distinguished by being a light gray in color.

DSC01229

20 discussions on “2003 GMC Yukon Bower Erratic / Not Working”

  1. Interesting perspective and I would suspect a good work around. I could only recommend it as a temporary repair as updating the blower motor is a more definitive repair. I am slightly concerned about voltage spikes from the toggle switch having an adverse effect on the rest of the electronics in the HVAC system.

  2. Sparky, all your info from the voltages to to the wiring has been very helpful. But I have come up with a few conclusions regarding the GM module circuit change. To clarify the pulse ground. The voltage swings up momentarily to to 12.64 when the unit is first turned on. Then it goes down to normal readings. This momentary voltage is not enough to spin an aged motor. Cycling the switches didn’t do anything for me at all. It would only come on randomly. Once the fan motor started, it would come on the rest of the day. Providing there wasn’t to much time during off times. It seemed that the cold Chicago temp was the problem. If your fan motor is in good working order like mine. I have a cheaper quick fix. The large red wire to the motor is the pulsing ground. You can use a 3M scotch lock terminal, a length of 12ga wire and a momentary switch. Wire it to ground for full fan motor start-up voltage. After you turn the AC/Heater on. Touch the switch and presto the fan will then start and work in normal operation. The switch cost about $5.00.
    Thanks, Carm in Chicago
    2004 Avalanche

  3. So, the problem ended up being a spread pin on the blower power connector. This is something I induced when I changed the original controller for not powering down the fan with the car off. Thanks so much for the site and the quick reply! I have bookmarked your site and have begun studying it.

    Thanks again-
    -Curt

  4. You need a new blower motor. If you go back a read the voltage test chart, you will see when using the black wire or chassis ground for your meter the voltage on the small purple wire should be exactly as you described. Also if you read the paragraph in red font you will see this is an ongoing issue and replacing the blower motor is the best way to remedy it.

  5. Sparky, great write up! Definitely helped me out, HOWEVER, my problem is not fixed. I replaced my blower speed controller on my auto HVAC 2003 Yukon, and all was well for a minute, then after a power recycle…nothing. When shooting for power at the controller, I get batt voltage on the red, ground on the black, and VERY NEAR batt voltage on the small purple with the key off. With key on the voltage drops eventually leveling at about 5v on fan speed high. I think that voltage is to high on the small purple signal wire, but why? Did I get a bad controller from the dealer? (I returned my first replacement for a loose connector). Any advice would be great. Thanks for the great site!

Share Your Experience: