2000 Cadillac Escalade

ID Status Date Year Make Model Transmission Type A/C Controls Public/Private
#14970 Closed 2000 Cadillac Escalade public

Im trying to get my AC/Heater blend doors to work correctly, i took the blend door actuator apart and greased it up and put it back together so it moves and everything, and alligned it to the middle, and then i followed the steps show here https://sparkys-answers.com/2011/08/hvac-actuator-recalibration-procedure.html but it doesnt fix it, possibly im pulling the wrong fuse? i dont have HVAC/ECAS fuse just a standard AC or Blower fuse, or possibly its different on a 2000 cadillac escalade? Thanks for the help

Austin

Sparky

According to GM there is no recalibration procedure for your vehicle. So either the actuator, control panel or wiring would be the likely causes in that order.

Write a reply

The ticket has been closed. If you feel that your issue has not been solved yet or something new came up in relation to this ticket, you can re-open it by clicking this link.